نوشته شده توسط : Likaibin

This blog will show you steps: XTOOL PAD2 calculate Chevy Onix pin code easily!

xtool-x100-pad-2-pro-tablet-key-progtammer-1

Tips: XTOOL X100 Pad 2 not only can read pin code and program key for many cars, but also has SPECIAL functions!

How XTOOL Scanner X100 Pad 2 read GM Chevrolet Onix pin code?

Connect XTOOL X100 Pad 2 Pro tablet with Chevy Onix OBD2 port.

Power on the device.

Go to “Immobilization” and select “GM” firstly.

xtool-x100-pad-2-read-gm-chevrolet-pin-code-2

It will automatically open XTOOL GM V27.03 software.

Choose “Immobilizer” and “Chevrolet”.

xtool-x100-pad-2-read-gm-chevrolet-pin-code-3

xtool-x100-pad-2-read-gm-chevrolet-pin-code-4

Choose the Chevrolet car region/market. (In this case, it’s South America)

Then select the car model: Onix.

xtool-x100-pad-2-read-gm-chevrolet-pin-code-5

Choose “Get security code” function.

xtool-x100-pad-2-read-gm-chevrolet-pin-code-6

Click car year “2013-2015”, turn ignition on and click “OK”.

xtool-x100-pad-2-read-gm-chevrolet-pin-code-7

Wait a second, XTOOL X100 Pad 2 Pro read out Chevrolet Onix 4-digit pin code as “1788”!

xtool-x100-pad-2-read-gm-chevrolet-pin-code-8



:: برچسب‌ها: XTOOL X-100 PAD 2,x100 pad, ,
:: بازدید از این مطلب : 206
|
امتیاز مطلب : 0
|
تعداد امتیازدهندگان : 0
|
مجموع امتیاز : 0
تاریخ انتشار : یک شنبه 13 بهمن 1398 | نظرات ()
نوشته شده توسط : Likaibin

One XTOOL X100 Pad2 user turned to us for help that his new XTOOL PAD2 failed to activate. When he filled in the info, the tablet screen shows “input is invalid: invalid Email, please input the right address” and then “This device still not be activated, please active it so that you could update the APP and the diagnostic software” with a black screen.

The customer has been trying over 2 weeks to solve this problem but nothing happened.

He tried to change another email but fail too.

Attached two photos to show this situation:

xtool-100-pad2-fail-to-active-1 xtool-100-pad2-fail-to-active-2

Customer:

Hello my X100 Pad2 is not right .The screen upside down. Win I try to activate it says INPUT IS INVALIB s/nx100pad2-12727.

After engineer checked the serial number of customer’ pad, they find that customer fill with the wrong activation code and it was stored in the machine so that he could not active successfully.

Tips for active XTOOL Diagnostic Tool:

Please make sure your information when filling in the brand.
Once you have registered with the wrong information, please reset the xtool product and then register again using the right information.



:: برچسب‌ها: XTOOL X-100 PAD 2,x100 pad, ,
:: بازدید از این مطلب : 172
|
امتیاز مطلب : 0
|
تعداد امتیازدهندگان : 0
|
مجموع امتیاز : 0
تاریخ انتشار : یک شنبه 13 بهمن 1398 | نظرات ()

صفحه قبل 1 2 3 4 5 ... 19 صفحه بعد